MODEL PRD 200-750

- Maximized pre-cooling
- Stacked tube-in-tube evaporator
- Two dependable demand type automatic condensate drains
- Non-cycling, hermetically sealed refrigeration system.
|
Model
|
PRD200x
|
PRD250x
|
PRD300x
|
PRD400x
|
PRD500x
|
PRD750x
|
|
Rated Flow (scfm)
1
|
200
|
250
|
300
|
400
|
500
|
750
|
|
Voltages (V/ph/Hz)
|
208-
230/3/60
|
208-
230/3/60
|
460/3/60
|
575/3/60
|
380-
420/3/50
|
380-
420/3/50
|
|
Power (kW)
2
|
1.30
|
1.94
|
1.94
|
2.62
|
2.62
|
3.60
|
|
Connection (in)
3
|
2 NPT
|
2 NPT
|
2 NPT
|
3 NPT
|
3 NPT
|
3 NPT
|
|
Height (in)
|
40
|
40
|
40
|
52
|
52
|
57
|
|
Width (in)
|
22
|
22
|
22
|
28
|
28
|
28
|
|
Depth (in)
|
48
|
48
|
48
|
51
|
51
|
65
|
|
Weight (lb)
|
405
|
415
|
416
|
457
|
498
|
625
|
x Standard 3 micron filter, emm™ (Energy Management
Monitor) and electric demand drain.
(1) Rated Flow Capacity - Conditions for rating dryers
are in accordance with CAGI (Compressed Air and Gas Institute) Standard
ADF 100: Refrigeration Compressed Air Dryers - Methods for Testing and
Rating. Conditions for rating above dryers are: compressed air at dryer
inlet: 100 psig (7 kgf/cm2) and 100°F (38°C); operating on
60 Hz power supply. Outlet pressure dew point at rated conditions is 38°F
(3°C) and pressure drop is less than 5 psi (0.34 kgf/cm2.
(2) At 35°F (2°C) evaporator and 100°F (38°C) ambient.
(3) BSP connections and DIN flanges available.
Note: Maximum operating pressure: 200psig (14 kgf/cm2;
Maximum operating temperature: 120°F (49°C).
|