Protects air systems exposed to temperatures below freezing
Produces pressure dew points of
-40°F (_40C), -100°F (-73°C)
Features
Consistent outlet pressure dew points - large desiccant
beds produce:
-40OF
(-400C) pressure dew point on a 10 minute cycle [equals an atmospheric
dew point of -71 OF (-570C)l
or
-100OF
(-730C) pressure dew point on a 4 minute cycle [equals
an atmospheric dew point of -122OF (-860C)l
Minimum
purge air usage - saving the heat of adsorption maximizes
the moisture holding capacity
of the purge air, minimizing the amount required
Long desiccant life - beds sized to prevent
fluidization plus slow and complete regeneration prevent
desiccant movement and deterioration
Heavy
duty purge exhaust muffler for quiet operation
Non-lubricated,
soft seated control valves
Highly accurate solid state timer
Standard 10 minute cycle ... gives increased desiccant life
over units operating on shorter cycles
Allows off -stream tower to fully repressurize before going
on-stream ... prevents bed movement and loss of pressure
downstream
Can
be field adjusted for 4 minute cycle if -100OF
(-73,C) pressure dew point is required
Front mounted control panel
Power on light
On-off
switch
Tower
pressure gauges
HF Series coalescing filter packages
Grade 5 oil removal
prefilter to 0.008 ppm (0.01 mg/ml) 0 Grade 6 dry desiccant afterfilter (I micron)
Stainless steel support screens and air cliff users (top and bottom of vessels)
easily
removed for cleaning
Filters out gross contaminants ... protects valves
Prevents channeling
Standard models are GSA certified attesting conformity to GSA standard CAN/CSA-C22.2 No.
236
|


|